The Smarty1-ORI is ruggedly and carefully built to perform in a variety of
industrial environments. To maximize reliability by using a urethane conformal
coating on all circuit boards, utilizing a hermetically-sealed optional keypad
and display,
The Smarty1-ORI has a minimum of 512K X 8 RAM for data
and 512K X 8 Flash memory allowing easy upgrade of run-time code. With the large memory capacity, a
minimum of 32,000 historical inputs with time and date stamp can be
stored. You can define data type
and collection period with our software.
One modem port and one RS-232C serial port for hand held data
collector/PC are standard. Kinds of Smarty1-ORI communication options are:
¨
Internal
2400 baud modem, supports standard CCITT V.22bis (2400 bps), Bell 212A (1200
bps), and Bell 103 (300 bps). Extension
off-hook detection.
¨
Cellular
telephone (Including GSM System)
¨
RS-422 and
RS-485 multi-drop
¨
Bell 202
lease line 1200 baud modem
¨
Packet radio
¨
Point-to-point
radio
The user can configure the Smarty1-ORI to activate an alarm when user-defined limits are exceeded,
including low battery power. Using
Eagle Researchˇ¦s Host software or CanGaSys Wizard, a user can program the Smarty1-ORI to alarm on almost any condition, such as box intrusion,
liquid levels, etc.
An audit trail file maintains a record of all
parameter changed. A complete history of alarms is also stored in a separate
file. Each entry includes the item value as well as the time and date the item
entered and exited alarm status. Using software may retrieve these un-editable
files.
Four programmable Form
A or C pulse inputs for low or high speed applications are standard. These inputs can be used for simple
pulse counters, or in more demanding applications such as card readers.
There are five multi-purpose digital I/O lines,
high-level functionality including pulse inputs, PWM (pulse width modulation)
outputs, and complex custom programmable inputs/outputs. Two I/O lines are connected to field
terminals through standard OPTO-22 modules. The other 3 I/O lines can be used
as either Form C or A relay outputs or status inputs.
The Smarty1-ORI is
designed for Class I, Division I and Class I, Division 2 hazardous location
applications.

Smarty1-ORI Interior View w/Optional Keypad/Display

Smarty1-ORI Hardware Specifications
|
Features |
Description |
|
|
Input
Power |
7-30 VDC. Two battery inputs with MTA
connectors. One power
supply/rechargeable battery input with screw terminals. One solar power input with screw
terminals. |
|
|
Consumption |
2.5 AH battery, 2-hr
charging per day @ 250 mA charge rate (5w) 2 mA average current. Less than 100 uA sleep current. |
|
|
Power
Monitoring |
Supply voltage monitoring
through a/d with low supply voltage interrupt |
|
|
Backup
Battery |
3.6 VDC lithium backup
battery: 10 years typical backup
of database and time/date during normal use. |
|
|
Processor |
High performance 16-bit
microcontroller |
|
|
Memory |
512K x 8
remotely-programmable FLASH program memory 512K x 8 battery-backed RAM data
memory |
|
|
Real-time
Clock |
Battery-backed, quartz
crystal controlled; +/- 1 sec/day typical accuracy; Programmable time
scheduled interrupt capability |
|
|
Internal
Inputs |
One ambient temperature
input; one supply voltage input |
|
|
Pulse
Inputs |
Four pulse inputs,
software programmable for Form A or C; high or low speed. Each counter is a six-digit
(0-999999) hardware counter with programmable interrupt support. Can be used for simple pulse
accumulation, and for more complex applications such as card readers |
|
|
Digital
I/Oˇ¦s |
Five multi-purpose,
memory-mapped digital i/o lines.
High-level functionality including pulse inputs, PWM (pulse width
modulation) outputs, and complex custom inputs/outputs. Two I/O lines are connected to field
terminals through standard OPTO-22 modules. The other 3 I/O lines can be used as either Form C or A
relay outputs (solid state 100 mA max ac/dc) or status inputs (50 V max. DC
only). |
|
|
Analog
Inputs |
Six general-purpose analog
inputs, 12-bit resolution, analog sampling, software Calibration. Nominal input ranges 0-5.12 VDC. A 250 ohm resistor in socket allows
4-20 mA or 0-5 VDC input for each channel. Each input has 3 screw terminals (Supply, Signal, and
Ground). Supply voltage jumper
selectable to connect the switched input voltage or allow connection of an
external source or 5 VDC buffered reference. |
|
|
RTD
Inputs |
Two 12-bit resolution RTD
inputs; 3-wire lead compensated with ground shield Connection; four screw terminals per input |
|
|
Communications |
One modem port with
extension off-hook detection.
Speed up to 2400 baud. One RS-232 ports with RX, TX, RTS, CTS, and
communication switch signals. Configurable speed up to 115,200 baud. Directly interfaces to modems,
radios, etc. via 6-position MTA or screw terminals. Communication protocols
selectable on a per port basis.
Eagle HexASCII, Modbus, Teledyne/Geotech, Valmet, BSAP |
|
|
Status
LED |
One software-controllable
LED for various function indications |
|
|
Expansion
Capability |
Additional connectors provide
redundant termination points to allow for Configuration flexibility. Two 10-position connectors allow for
expansion over the I2C communication bus. Optional isolated analog
output modules and optional serial ports |
|
|
Transducers/Sensors
Accuracy Specifications |
||
Differential
Transducer
|
Accuracy:+0.25% FS
including all external effects over ˇV20˘X F to +140˘X F |
|
|
Pressure
Transducer |
Accuracy:+0.25% FS
including all external effects over ˇV20˘X F to +140˘X F |
|
RTD Sensor
|
+1˘XF |
|
The Talon series
of products has been designed as a Windows® based setup,
configuration, device management, and polling tool for the Eagle Research
family of products by Eagle Research. Based on The
Talon style format, Ngquip authorized by Eagle following Talon develops a
tool of configuration and management called CangaSysWiizard Chinese. Talon SCADA is suitable for larger applications,
polling multiple devices over several Communications ports.

CanGaSysWizard
Chinese Windows® basedˇK. Customer
driven.