Text Box:  
Product Information
Text Box:

 

 


Reliability

The Smarty1-ORI is ruggedly and carefully built to perform in a variety of industrial environments. To maximize reliability by using a urethane conformal coating on all circuit boards, utilizing a hermetically-sealed optional keypad and display,

 

Memory

The Smarty1-ORI has a minimum of 512K X 8 RAM for data and 512K X 8 Flash memory allowing easy upgrade of run-time code.  With the large memory capacity, a minimum of 32,000 historical inputs with time and date stamp can be stored.  You can define data type and collection period with our software.

 

Communications

One modem port and one RS-232C serial port for hand held data collector/PC are standard.  Kinds of  Smarty1-ORI communication options are:

¨      Internal 2400 baud modem, supports standard CCITT V.22bis (2400 bps), Bell 212A (1200 bps), and Bell 103 (300 bps).  Extension off-hook detection.

¨      Cellular telephone (Including GSM System)

¨      RS-422 and RS-485 multi-drop

¨      Bell 202 lease line 1200 baud modem

¨      Packet radio

¨      Point-to-point radio

 

User-Definable Alarms

The user can configure the Smarty1-ORI to activate an alarm when user-defined limits are exceeded, including low battery power.  Using Eagle Researchˇ¦s Host software or CanGaSys Wizard, a user can program the Smarty1-ORI to alarm on almost any condition, such as box intrusion, liquid levels, etc.

 

Audit Trail and Alarm Log

An audit trail file maintains a record of all parameter changed. A complete history of alarms is also stored in a separate file. Each entry includes the item value as well as the time and date the item entered and exited alarm status. Using software may retrieve these un-editable files.

 

Pulse Inputs

Four programmable Form A or C pulse inputs for low or high speed applications are standard.  These inputs can be used for simple pulse counters, or in more demanding applications such as card readers.

 

Digital Inputs / Outputs

There are five multi-purpose digital I/O lines, high-level functionality including pulse inputs, PWM (pulse width modulation) outputs, and complex custom programmable inputs/outputs.  Two I/O lines are connected to field terminals through standard OPTO-22 modules. The other 3 I/O lines can be used as either Form C or A relay outputs or status inputs.

 

Hazardous Location

The Smarty1-ORI is designed for Class I, Division I and Class I, Division 2 hazardous location applications.

 

 

 

 

 

 

 

 

Smarty1-ORI Interior View w/Optional Keypad/Display

 

 

Smarty1-ORI   Hardware Specifications

 
 

 


Features

Description

Input Power

7-30 VDC.  Two battery inputs with MTA connectors.  One power supply/rechargeable battery input with screw terminals.  One solar power input with screw terminals.

Consumption

2.5 AH battery, 2-hr charging per day @ 250 mA charge rate (5w) 2 mA average current.  Less than 100 uA sleep current.

Power Monitoring

Supply voltage monitoring through a/d with low supply voltage interrupt

Backup Battery

3.6 VDC lithium backup battery:  10 years typical backup of database and time/date during normal use.

Processor

High performance 16-bit microcontroller

Memory

512K x 8 remotely-programmable FLASH program memory 512K x 8 battery-backed RAM data memory

Real-time Clock

Battery-backed, quartz crystal controlled; +/- 1 sec/day typical accuracy; Programmable time scheduled interrupt capability

Internal Inputs

One ambient temperature input; one supply voltage input

Pulse Inputs

Four pulse inputs, software programmable for Form A or C; high or low speed.  Each counter is a six-digit (0-999999) hardware counter with programmable interrupt support.  Can be used for simple pulse accumulation, and for more complex applications such as card readers

Digital I/Oˇ¦s

Five multi-purpose, memory-mapped digital i/o lines.  High-level functionality including pulse inputs, PWM (pulse width modulation) outputs, and complex custom inputs/outputs.  Two I/O lines are connected to field terminals through standard OPTO-22 modules.  The other 3 I/O lines can be used as either Form C or A relay outputs (solid state 100 mA max ac/dc) or status inputs (50 V max. DC only).

Analog Inputs

Six general-purpose analog inputs, 12-bit resolution, analog sampling, software    Calibration.  Nominal input ranges 0-5.12 VDC.  A 250 ohm resistor in socket allows 4-20 mA or 0-5 VDC input for each channel.  Each input has 3 screw terminals (Supply, Signal, and Ground).  Supply voltage jumper selectable to connect the switched input voltage or allow connection of an external source or 5 VDC buffered reference.

RTD Inputs

Two 12-bit resolution RTD inputs; 3-wire lead compensated with ground shield    Connection;  four screw terminals per input

Communications

One modem port with extension off-hook detection.  Speed up to 2400 baud. One RS-232 ports with RX, TX, RTS, CTS, and communication switch signals. Configurable speed up to 115,200 baud.  Directly interfaces to modems, radios, etc. via 6-position MTA or screw terminals. Communication protocols selectable on a per port basis.  Eagle HexASCII, Modbus, Teledyne/Geotech, Valmet, BSAP

Status LED

One software-controllable LED for various function indications

Expansion Capability

Additional connectors provide redundant termination points to allow for Configuration flexibility.  Two 10-position connectors allow for expansion over the I2C communication bus. Optional isolated analog output modules and optional serial ports

 

Transducers/Sensors Accuracy Specifications

 

Differential Transducer

Accuracy:+0.25% FS including all external effects over ˇV20˘X F to +140˘X F

Pressure Transducer

Accuracy:+0.25% FS including all external effects over ˇV20˘X F to +140˘X F

RTD Sensor

+1˘XF

 

The Talon series of products has been designed as a Windows® based setup, configuration, device management, and polling tool for the Eagle Research family of products by Eagle Research.

Based on The Talon style format, Ngquip authorized by Eagle following Talon develops a tool of configuration and management called CangaSysWiizard Chinese.

Talon SCADA is suitable for larger applications, polling multiple devices over several Communications ports.

 

 

 

       

 

 

 

 

CanGaSysWizard Chinese

Windows® basedˇK. Customer driven.

 
 

 

 


                 Back to Products Line or Home page