CanGaSys

Top -X-P TYPE

Top Entry Pilot Operated Precise Pressure Regulator

High Accuracy

High turn down ratio

Large flow capacity

Low noise level

Bubble tight lock up

Easy, fast and inexpensive maintenance

Low cost of acquisition

Flexible extensive function:

Intelligent Peak time control;

Feed back regulator etc.

 
 

 

 NGQUIP CANADA

                                                              

 

Top -X-P is light, simple, superior performance of pressure control (¡Ó 1% accuracy),

high flow capacity and the most reliable durability comparing with all existing same

designed type of regulators in this industry.

 

Application:

For natural gas transmission and/or distribution systems.

Also used in several other industrial processes.

 

For abnormal pressure protection,

Select Top -X-P + SSV ¡V IH or IPH (& HILO for dual function).

 

 

                   

 

The operating principle of Top-X-P creates a pressure regulator with

extraordinary speed of response to flowing demand variations and

extremely accurate pressure adjustments, while maintaining extremely low ¡§lock-up¡¨.

 

LOW COST AND EASY MAINTENANCE

Less parts required,

  Simplification and one-man operation

  of routine maintenance,

  Top entry friendly design, without

  moving the valve from the Pipeline!

  Just have few nuts pop-off for

  maintenance.

 

 

 

 

 

 

Technical Characteristics

Maximum Pressures

 

NOTES:

1)      For ductile iron body the maximum operating pressure is 18 bars.

2)      Max. regulation deviation is ¡Ó1%

3)      Max. lock-up deviation is 5%

4)      Flanges according to ANSI B.16.5,        

      Classes 150#RF, 300#RF and 600#RF, or

      RTJ        

5)      Maximum operating pressures up to 100 bars
(according to ANSI B.16.5.a-1998)

6)      Outlet pressure range: 0.7 ~ 63.5 bars

   

150#

300#

600#

 

19.7 bar

51 bar

102 bar

 

Lock-up group (DIN 3380)

SG 10

 

Regulation group (DIN 3380)

RG 2.5

Tightness  (ANSI B.16.104)

Total

 

 

 

 

 

 

 

 

 

 

   

 

 

    

 

 

 

Flow Coefficient

Æ

CV

Kg

Restriction %

1"

14.5

450

25, 50, 75, 100

2"

54.8

1700

25, 50, 75, 100

3"

106.4

3300

25, 50, 75, 100

4"

185.7

5760

25, 50, 75, 100

 6"

403

13000

25, 50, 75, 100

Sizing Formulas

Sub-Critic Flow

Critic Flow

P2/P1 ³ 0.53

P2/P1 < 0.53

where:
Q = Maximum regulator flow
 (Nm3/hr)
KG = Regulator coefficient (See table)

P1 = Regulator input pressure (bar - abs)
P2 = Regulator output pressure (bar - abs)

NOTES  :


1.    We suggest that the regulator sizing calculation consider a minimum safety factor of

      20% above the calculated value.      

2.        For application with other gases, the calculated flow shall be converted to an equivalent

      flow in natural gas, using the table below: