CanGaSys Top -X-P
TYPE |
Top Entry Pilot Operated Precise Pressure Regulator |
||
|
High Accuracy High turn down ratio Large flow capacity Low noise level Bubble tight lock up Easy, fast and inexpensive maintenance Low cost of acquisition Flexible extensive function: Feed back regulator etc.
|
|||
Top -X-P is light, simple,
superior performance of pressure control (¡Ó 1% accuracy),
high flow capacity and the
most reliable durability comparing with all existing same
designed type of
regulators in this industry.
Application:
For natural gas transmission and/or
distribution systems.
Also used in several other industrial processes.
For abnormal pressure protection,
Select Top -X-P + SSV ¡V IH or IPH (&
![]()




The operating principle of Top-X-P creates a pressure regulator with
extraordinary speed of response to flowing demand variations and
extremely accurate pressure adjustments, while maintaining extremely low
¡§lock-up¡¨.
LOW COST AND EASY MAINTENANCE
Less parts required,
Simplification and one-man operation
of routine maintenance,
Top entry friendly design, without
moving the valve from the Pipeline!
Just have few nuts pop-off for
maintenance.


Technical Characteristics
|
Maximum Pressures |
|
NOTES: 1)
For ductile iron body the maximum
operating pressure is 18 bars. 2)
Max. regulation deviation is ¡Ó1% 3)
Max. lock-up deviation is 5% 4)
Flanges according to ANSI
B.16.5,
Classes 150#RF,
300#RF and 600#RF, or RTJ 5)
Maximum operating pressures up to
100 bars 6)
Outlet pressure range: 0.7 ~ 63.5 bars |
||
|
150# |
300# |
600# |
|
|
|
19.7 bar |
51 bar |
102 bar |
||
|
|
||||
|
Lock-up group (DIN 3380) |
SG 10 |
|
||
|
Regulation group (DIN 3380) |
RG 2.5 |
|||
|
Tightness (ANSI B.16.104) |
Total |
|||
Flow Coefficient
|
Æ |
CV |
Kg |
Restriction
% |
|
1" |
14.5 |
450 |
25, 50, 75, 100 |
|
2" |
54.8 |
1700 |
25, 50, 75, 100 |
|
3" |
106.4 |
3300 |
25, 50, 75, 100 |
|
4" |
185.7 |
5760 |
25, 50, 75, 100 |
|
6" |
403 |
13000 |
25, 50, 75, 100 |
Sizing Formulas
|
Sub-Critic Flow |
Critic Flow
|
|
P2/P1 ³
0.53 |
P2/P1
< 0.53 |
|
|
|
where:
Q = Maximum regulator flow (Nm3/hr)
KG = Regulator coefficient (See table)
P1 = Regulator input pressure (bar - abs)
P2 = Regulator output pressure (bar - abs)
NOTES :
1. We
suggest that the regulator sizing calculation consider a minimum safety factor
of
20% above the calculated value.
2.
For application with other gases,
the calculated flow shall be converted to an equivalent
flow
in natural gas, using the table below: